Vacuum centrifuge when ever centrifugation, Vacuuming and heating is required to rapidly concentrate Multiple heart sensitive samples efficiently recycle biological or analytical samples in application in life science, chemistry and pharmacy.
Bio Gene vacuum concentrator can be used with confidence to get effective Results.
Centrifuge force generated by Bio Gene vacuum concentrator due to spinning creates pressure gradient within the solvent in the Rotor tubes. There by boiling accurse from Top to bottom thus the gentle evaporation takes place in all the samples simul tenaciously due to health vacuuming and centrifugation efficient recycle of Biological & Analytical samples can be done in wide gamut of application in life science Pharmacy Chemistry etc.
Bio Gene Table Vacuum centrifuge sare used in application of Petroleum Products, Hematology, Microbiology Chemical Engineer Nano Physics etc. at Industries, Research Centers University.
Bio Gene Centrifuges are manufactured after a careful Expertise of 20 Years taking the utility of max use by the customer.
CENTRIFUGE BOWL : The Centrifuge Bowl is made of thick Stainless Steel with joint less construction of Deep drawn Technology.
AUTOMATIC BALANCED MOTOR Bio Gene Centrifuge has a unique feature of imbalance detection thereby the Intelligence of microprocessor positions the motor for the Uneven imbalance safety.
LID :Bio Gene Research Team has carefully designed the lid with a paramount feature of Users Safety by providing the Lid with 300% extra Impact load test.
The lid is aerosol Tight to ensure the same.
The lid is providing with Electronic and Mechanical Lock for ensured operator security as well.
OUTER BODY: Bio Gene Centrifuge has outer body made of Thick CRC Steel duly Powder Coated for a long lasting life and better exterior. Inner chambers vessel (bowl) is made of reliable steel structure of 316 stainless steel grade.
DIGITAL TIMER : Lab application demands to have the centrifugation for determined time at the Relative Centrifugation force on the samples.
Bio Gene Centrifuge has Digital Timer to enable the User Scientist to Preset the Time from 0 to 99 Hrs 59 minutes.
DIGITAL SPEED INDICATOR :Bio Gene designs enables to have the Operator friendly Feature of Microprocessor based Digital Speed Indication with Pre Set Values programmable.
Digital Relative Centrifugal Force Indicator :
Our Centrifuge is capable to have the RCF displayed on the operation of the desired Speed automatically.
COMPACT DESIGN LESS WEIGHT : also are important features of our Careful inputs for the Centrifuge .
Prime Mover : Alternative Current 220 volts Single phase 50Hz 10Ampheres.
NOISE LEVEL :Bio Gene machine have a very low noise level of 65 decibels.