MODEL BIO GENE BTI/HPLC-6002B High pressure gradient system which has 2 sets constant-current pumps and 1 set gradient mixer. The gradient mixer is our patent with high performance, it has 16:9 TFT color screen which support imputing and displaying for all information through instrument touch screen when offline. Choosing the auto-injector, quantify with injector, mobile phase through the needle, computer control for the sample volume, and can change the sample input volume without replacing the quantify hoop. It’s very convenient for client’s operation.
Medicine analysis, food safety, environmental detection, oil and chemical analysis, animal and aquaculture, colleges and universities, scientific research and so on
1) Patent gradient mixer, has high performance, dead volume <10μL.
2) Dual piston reciprocating and series pump. One is a main adsorption piston; the other is an assistant piston, to make the flow stable.
3) The detector use 24 bits AD transducer, to ensure low noise, low drift and high sensibility. Having auto-detection when starting up, can check and set the deuterium lamp status.
4) Using International advanced high pressure injector technique. The quantify injector, mobile phase pass through injection, computer control for the sample volume can reduce residual sample. It can change the sample input volume without replacing the quantify hoop conveniently.
5) Beautiful and convenient surface. Stand-alone color screen touch control. Each unit has 16:9 TFT color screen, which support imputing and displaying for all information through instrument touch screen when offline.
6) Powerful control function with intelligent anti-control Software. High-level imitating anole chromatogram processing software with data acquisition interface. It’s very convenient for customer to operate in one key. Powerful auto data analysis function ensures your sample analysis, data display, data analysis and report efficiently.
HPLC600-02P High-Pressure Gradient Pump | |
Peak Operating Pressure | 45Mpa,Stainless Steel Pump |
Pressure Error | ±0.02MPa |
Flow Rate Range | 0.001-9.999mL/min |
Flow Rate Precision | ±5% |
Flow Rate Repeatability | RSD≤0.1% |
Power | 220v±10%,50Hz,250W |
Size | 520mm x 420mm x 160mm(W*H*D) |
HPLC600-01D UV Detector | |
Wave length | 190-680nm |
Wave length Error | ≤±1nm |
Baseline Noise | ≤2 x 10-5AU (Methyl Alcohol, 1mL/min, 254nm, 20℃) |
Wave length Repeatability | 0.2nm |
Flow Cell | 8μL |
Drift | ≤5 x 10-4AU/h ( Methyl Alcohol, 1mL/min, 254nm, 20℃) |
Limit of Detection | ≤2 x 10-9g/mL (Naphthalene Methyl Alcohol Solvent) |
Sample Value | Maximum 2mL,6 x 25=150units |
Sample Volume | 0-1mL, Adjustable |
Sample Residual | <0.02% |
Column Oven | |
Temperature Control | Room Temperature+5℃-80℃ |
Constant Temperature Accuracy | ±1℃ |
Constant Temperature Precision | 0.1℃ |
Overall Instrument | |
Qualitative Analysis | RSD6≤0.2% |
Quantitative Repeatability | RSD≤0.2% |
Sample Residual | ≤0.01% |
Gradient Error | ≤0.5% |
Related Products can be Chosen
Arcrus 5 automatic injector system