Whenever stability test are of prime importance under ICH guidelines within Q1A22 parameter BioGene Stability chamber guide through the Harmonization process to enable qualify for License. Living cells study, New Drug Development and pharmaceutical compounds, License are obtain by using BioGene Humidity chamber under the ICH-Q1AR2 Guidelines with ease.

Bio Gene test chamber are provided with state of art 21 CFR part  11 Software which makes the user comfortable. 

BIOGENE Stability Chambers have found different application shelf life testing, accelerated aging, steady state in electronic components, Sim card, industrial and biological materials.

 

BIOGENE Stability Chambers meet Photo stability studies in Pharma, Plastics, composites, Adhesives, Textiles. Cosmetic, Food & Beverages, Personal care Biomedical storage, life science, Electronics etc in compliance with ICH guideline Q1A along with state of art 21 CFR Part 11 software.

Bio-Gene Temperature and Humidity Chamber have:

  • Temperature Range from  5°C to 60°C,
  • Relative Humidity from 5% to 90 %RH ±3RH
  • Touch Screen Type, Programmable Controller
  • Dual Turbo Fan Circulation and Fluorescent Lamp
  • Low Water Level Alarm System
  • Built-In RS-485 Communication Interface
  • Optional Temperature/Humidity Chart Recorder without Microprocessor/PID/Digital Control with touch-screen type controller provides precise temperature control from  5°C to 60°C, relative humidity control from 5% to 90 %RH, timer, alarm, auto-tuning and auto stat stop function

Programmable, 999 cycle large capacity program controller, various alarm function, self-diagnostic, high accuracy with 0.1%, 

Built-In RS-485 Interface enables the chamber easily hook-up to personal computer

Silent Dual Turbo Fan motor circulate air and maintain uniforms temperature in the chamber and quiet operation and auto-defrost function

Safety and Convenience over temperature and current protection capability ensure user safety and adjustable sliding rack

Sliding Water Storage Tank and automatic water supplying device.

  • Standards : ICH-Q1AR2
  • ISO,EN, CE, Electro magnetic 
  • MDD :- 93/42/EEC
  • IEC  60068-2-38
  • EN 61000-6-1 : 2001
  • Electromagnetic Compatibility Directive (89)/336/EEC)
  • EN: 60101, ISO, CE
  • Touch Screen Type 5.7’/ 7.0”
  • Double walled with PUF insulation of 80-150 mm
  • Inner Chamber: Stainless Steel 304
  • Outer Chamber: Mild Steel Powder Coated
  • Danfoss Tecumseh CFC free cooling system with hermetically sealed compressor with temperature sensors
  • Stainless steel Trays
  • Inner Door: Full-length inner glass door 
  • WiFi & LAN based data Communication
  • Fluorescent light (324 liters & above)
  • Forced air circulation for uniform temperature
  • Safety devices: Low & high temperature cut-off settable thermostats & high humidity cut-off device
  • Audio/Visual alarms for deviations
  • DATA LOGGING
    data Logging up logs for Temp.& Humidity
    RS232 Data Logger
DESCRIPTION BTI-HC-171 BTI-HC-280 BTI-HC-420 BTI-HC-560 BTI-HC-840
Temperature Range 5°C to 60°C
Temperature Accuracy ± 0.2°C
Temperature Uniformity ± 1°C
Humidity Accuracy ± 2% RH
Humidity Uniformity ± 3% RH
Temperature sensor 3 wire RTD
Humidity range 5% RH to 90% RH
Humidity Stability ±2% or Better
Humidity Sensor Capacitive
Light 15000 LUX (optional)
Interior construction Stainless steel 304
Exterior Construction CRCA Powder coated
Internal Door Glass Sheet door with complete visibility of components.
Option for electrical interface Standard connector
Trays SS 304 perforated.
Electrical 220 to 240 volts AC 50 Hz single phase
Timer cyclic 0 to 24 hrs day night
Alarm Audio and visual
Dimensions 505 x 415 x 830 570 x 550 x 875 700 x 640 x 900 700 x 700 x 1100 825 x 825 x 120
Capacity 171 ltrs 280 ltrs 420 ltrs 560 ltrs 840 ltrs